S-(5'-Adenosyl)-L-methionine chloride
Reference standards.
Inquire / Order:
manager@chemfaces.com
Technical Inquiries:
service@chemfaces.com
Tel:
+86-27-84237783
Fax:
+86-27-84254680
Address:
1 Building, No. 83, CheCheng Rd., Wuhan Economic and Technological Development Zone, Wuhan, Hubei 430056, PRC
Providing storage is as stated on the product vial and the vial is kept tightly sealed, the product can be stored for up to
24 months(2-8C).
Wherever possible, you should prepare and use solutions on the same day. However, if you need to make up stock solutions in advance, we recommend that you store the solution as aliquots in tightly sealed vials at -20C. Generally, these will be useable for up to two weeks. Before use, and prior to opening the vial we recommend that you allow your product to equilibrate to room temperature for at least 1 hour.
Need more advice on solubility, usage and handling? Please email to: service@chemfaces.com
The packaging of the product may have turned upside down during transportation, resulting in the natural compounds adhering to the neck or cap of the vial. take the vial out of its packaging and gently shake to let the compounds fall to the bottom of the vial. for liquid products, centrifuge at 200-500 RPM to gather the liquid at the bottom of the vial. try to avoid loss or contamination during handling.
Appl. Sci. 2021, 11(22), 10552
J Cell Physiol.2020, 10.1002
Pharmacognosy Journal.2022, 14,4,327-337.
J Herbmed Pharmacol.2018, 7(4):280-286
Molecules.2023, 28(8):3376.
Nutrients.2021, 13(8):2901.
Nature Ecology & Evolution2020, doi: 10.1038
Food Sci Nutr.2019, 8(1):246-256
Biomolecules.2024, 14(5):589.
Appl. Sci.2020, 10(5),1713.
Related and Featured Products
Anal Chim Acta. 2013 Jul 25;788:32-8.
Amperometric sensing of norepinephrine at picomolar concentrations using screen printed, high surface area mesoporous carbon.[Pubmed:
23845478]
METHODS AND RESULTS:
Norepinephrine (NE) is detected amperometrically using the enzyme Phenylethanolamine N-methyl transferase and cofactor S-(5'-Adenosyl)-L-methionine chloride dihydrochloride with disposable screen printed mesoporous carbon electrodes. The role of internal surface area and pore size of the mesoporous carbon is systematically examined using soft-templated, mesoporous silica-carbon powders with highly microporous walls obtained from etching of the silica to produce powders with surface areas ranging from 671-2339 m(2)g(-1). As the surface area increases, the sensitivity of the biosensor at very low NE concentrations (0-500 pg mL(-1)) in phosphate buffered saline (PBS) increases just as the current signal increases with respect to the NE concentration of 81-1581 μA mL ng(-1) cm(-2) for the mesoporous carbons.
CONCLUSIONS:
The best performing electrode provides similar sensitivity in whole rabbit blood in comparison to PBS despite no membrane layer to filter the non-desired reactants; the small (<5 nm) pore size and large internal surface area acts to minimize non-specific events that decrease sensitivity.